arrow Are you looking for a solution for your industry or do you have a technical problem that needs solving?

Clivet chiller and Haier MRV – Lećevica Waste Management Centre

Clivet water chiller and Haier MRV (VRF) system – Lećevica Waste Management Centre. Reference by MB Frigo Grupa.

For Lećevica Waste Management Centre, MB Frigo Grupa delivered: Clivet water chiller and Haier MRV (VRF) system.

About the project: Lećevica Waste Management Centre

The Lećevica Waste Management Centre is the regional waste management centre for Split-Dalmatia County. In such facilities, combining a hydronic system with an MRV system makes it possible to choose the most suitable solution for each type of space – administrative, technical and ancillary.

Solution: Clivet water chillers and hydronic system

In a hydronic system with Clivet water chillers, a central unit (a chiller, or a heat pump in reversible versions) produces chilled or hot water, which is piped to fan coils and cassette units in the individual spaces. The refrigerant stays in the outdoor unit and only water enters the building.

What this means for designers and investors:

  • Safety for occupants – no refrigerant is distributed through the rooms, an advantage in public, educational and healthcare buildings.
  • Flexibility – terminal units are selected according to the use and acoustic requirements of each space.
  • Easy extension and renovation – the hydronic network can be extended without work on the refrigerant circuit.
  • Integration with building management – system operation is monitored and optimised via the BMS.

Solution: Haier MRV (VRF) system

Haier MRV (VRF – variable refrigerant flow) connects one or more outdoor units to a large number of indoor units and enables independent temperature control by room or zone. Inverter compressors adjust the refrigerant flow to the actual load, so the system uses only as much energy as the building needs at any given moment.

What this means for designers and investors:

  • Zoning – every retail or office space has its own control.
  • Part-load efficiency – the mode in which the system operates for most of the year.
  • Flexible choice of indoor units – cassette, ducted or wall-mounted units to suit each space; cassette units distribute air evenly in open areas.
  • Lower space requirements – no plant room or large air ducts.
  • Central control – operation of the entire building managed and monitored from one place.

Why MB Frigo Grupa

Haier is one of the world’s leading manufacturers of air-conditioning equipment and heat pumps. MB Frigo Grupa has been active in air conditioning and refrigeration since 1981. For air-conditioning projects it provides technical support for designers in selecting and sizing systems, equipment supply, and support with commissioning, service and maintenance.

Frequently asked questions

When does it make sense to combine hydronic and MRV systems in one building?

When a building has spaces with very different uses: a hydronic system with a water chiller suits larger spaces and central energy generation, while an MRV system suits smaller spaces that need separate control. The combination gives the optimal solution for every part of the building.

What is the difference between a hydronic and a VRF system?

A hydronic system uses water as the transfer medium, so the refrigerant stays in the outdoor unit. A VRF system distributes refrigerant directly to the indoor units. Hydronic systems are better suited to large and public buildings, VRF to buildings with many smaller zones.

Technical details

  • Project: Lećevica Waste Management Centre
  • Segment: municipal infrastructure
  • Air-conditioning systems: Clivet water chiller and Haier MRV (VRF) system
  • Location: Lećevica, Split-Dalmatia County