Clivet air conditioning 720 kW – Petrova Hospital, Zagreb

Clivet water chillers, fan coils and cassette units (720 kW) – Petrova Clinic for Gynaecology and Obstetrics, Zagreb. Reference by MB Frigo Grupa.

For Petrova Clinic for Gynaecology and Obstetrics, MB Frigo Grupa delivered: Clivet water chillers, fan coils and cassette units. Total capacity: 720 kW.

About the project: Petrova Clinic for Gynaecology and Obstetrics, Zagreb

The clinic in Petrova Street is Croatia’s central gynaecology and obstetrics institution and part of the University Hospital Centre Zagreb. In maternity wards and hospital departments, air conditioning must run continuously and reliably, with separate control of individual rooms.

More about the project: kbc-zagreb.hr.

Solution: Clivet water chillers and hydronic system

In a hydronic system with Clivet water chillers, a central unit (a chiller, or a heat pump in reversible versions) produces chilled or hot water, which is piped to fan coils and cassette units in the individual spaces. The refrigerant stays in the outdoor unit and only water enters the building.

What this means for designers and investors:

  • Safety for occupants – no refrigerant is distributed through the rooms, an advantage in public, educational and healthcare buildings.
  • Flexibility – terminal units are selected according to the use and acoustic requirements of each space.
  • Easy extension and renovation – the hydronic network can be extended without work on the refrigerant circuit.
  • Integration with building management – system operation is monitored and optimised via the BMS.

Why MB Frigo Grupa

Clivet is an Italian specialist in cooling, heating and air-treatment systems. MB Frigo Grupa has been active in air conditioning and refrigeration since 1981. For air-conditioning projects it provides technical support for designers in selecting and sizing systems, equipment supply, and support with commissioning, service and maintenance.

Frequently asked questions

What are the requirements for air conditioning in hospitals and maternity wards?

Hospital systems must run continuously, with separate control by room, quiet operation and reliable capacity redundancy. In maternity and neonatal wards, stable temperature and air quality are especially important.

What is the difference between a hydronic and a VRF system?

A hydronic system uses water as the transfer medium, so the refrigerant stays in the outdoor unit. A VRF system distributes refrigerant directly to the indoor units. Hydronic systems are better suited to large and public buildings, VRF to buildings with many smaller zones.

Technical details

  • Project: Petrova Clinic for Gynaecology and Obstetrics, Zagreb
  • Investor: KBC Zagreb
  • Segment: healthcare – hospitals
  • Air-conditioning systems: Clivet water chillers, fan coils and cassette units
  • Capacity: 720 kW
  • Location: Zagreb
  • Website: kbc-zagreb.hr